توضیحات
Description
The dual channel Repeater Power Supply, D5014D module, is a high integrity analog input interface suitable for applications requiring SIL 3 level (according to IEC 61508:2010 Ed.2) in safety related systems for high risk industries.
Provides a fully floating dc supply for energizing conventional 2/3 wires 4-20 mA, active or passive, transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The circuit allows bi-directional communication signals, for Hart transmitters.
Mounting on standard DIN-Rail, with or without Power Bus, or on customized Termination Boards, in Safe Area / Non Hazardous Location or in Zone 2 / Class I, Division 2 or Class I, Zone 2.
Features
- Systematic capability SIL 3
• 2 fully independent channels.
• Input from Zone 0 (Zone 20) / Division 1, installation in Zone 2 / Division 2
• 4-20 mA Input / Output Signal Active-Passive / Source-Sink
• Hart compatible.
• Input and Output short circuit proof.
• High Accuracy.
• Three port isolation, Input/Output/Supply.
• EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system.
• In-field programmability by DIP Switch.
• Type Approval Certificate DNV for marine applications.
• High Density, two channels per unit.
• Simplified installation using standard DIN-Rail and plug-in terminal blocks, with or without Power Bus, or customized Termination Boards.
• 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier.
Supply
18-30 Vdc
Channels
2 (1 Channel: D5014S)
SIL level
SIL 3
Supply
24 Vdc nom (18 to 30 Vdc), reverse polarity protected.
Current consumption: 90 mA (D5014D), 45 mA (D5014S), @ 24 Vdc with
20 mA output, typical.
Power dissipation: 1.35 W (D5014D), 0.68 W (D5014S), @ 24 Vdc with
20 mA output, typical.
Input
4 to 20 mA (separately powered input, voltage drop ≤ 0.5 V) or 4 to 20 mA
(2 wires Tx current limited ≈ 25 mA), reading range 0 to 24 mA.
Transmitter line voltage: 15.0 V typical, 14.5 V minimum, @ 20 mA.
Output
4 to 20 mA, on max. 550 Ω load in source mode (typical 12 V compliance);
V min. 8 V @ 0 Ω load V max. 30 V in sink mode, current limited ≈ 25 mA
or 1 to 5 V on internal 250 Ω shunt (or 2 to 10 V on internal 500 Ω shunt on
request). Output current duplication available (D5014D).
Response time: 5 ms (0 to 100 % step change).
Performance
Ref. Conditions: 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
Calibration accuracy: ≤ ± 0.1 % FSR.
Linearity accuracy: ≤ ± 0.05 % FSR.
Temp. influence: ≤ ± 0.01 % FSR on zero/span for a 1 °C change.
Isolation
I.S. In/Out 2.5 kV; I.S. In/Supply 2.5 kV; I.S. In/I.S. In 500 V; Out/Supply
500 V; Out/Out 500 V.
Environmental conditions
Operating temperature: temperature limits –40 to +70 °C.
Storage temperature: temperature limits –45 to +80 °C.
Safety description
Associated apparatus and non-sparking electrical equipment.
Uo = 25.9 V, Io = 92 mA, Po = 594 mW at terminals 7-8, 9-10.
Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals 8-11, 10-12.
Ui = 30 V, Ii = 128 mA, Ci = 0 nF, Li = 0 nH at terminals 8-11, 10-12.
Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.
Mounting
DIN-Rail 35 mm, with or without Power Bus or on custom Term. Board.
Weight: about 155 g (D5014D), 130 g (D5014S).
Connection: by polarized plug-in disconnect screw terminal blocks to
accommodate terminations up to 2.5 mm² (13 AWG).
Dimensions: Width 12.5 mm, Depth 123 mm, Height 120 mm.